565 research outputs found

    Wearable and Implantable Wireless Sensor Network Solutions for Healthcare Monitoring

    Get PDF
    Wireless sensor network (WSN) technologies are considered one of the key research areas in computer science and the healthcare application industries for improving the quality of life. The purpose of this paper is to provide a snapshot of current developments and future direction of research on wearable and implantable body area network systems for continuous monitoring of patients. This paper explains the important role of body sensor networks in medicine to minimize the need for caregivers and help the chronically ill and elderly people live an independent life, besides providing people with quality care. The paper provides several examples of state of the art technology together with the design considerations like unobtrusiveness, scalability, energy efficiency, security and also provides a comprehensive analysis of the various benefits and drawbacks of these systems. Although offering significant benefits, the field of wearable and implantable body sensor networks still faces major challenges and open research problems which are investigated and covered, along with some proposed solutions, in this paper

    Design and structural dynamic characteristics of an irregular staircase under earthquake loading

    Get PDF
    Reinforced concrete staircases are structurally designed as cantilevered, slab type or beam-slab type. Within this study an irregular cantilevered staircase is studied and its structural dynamic characteristics are explored. An eigen-value modal analysis is performed to determine the mode shapes, their corresponding modal participation factors and natural periods of vibration. The highest modes of interest are identified. Following on that, a scaled record of a previous historical earthquake was applied within a direct integration time-history analysis in order to assess the performance of that irregular stair case under earthquake loading. That load was applied within two perpendicular load cases representing the different possible directions of earthquake vibrations in which the effect of the structure irregularity was assessed per direction. The structure was found to have large drifts creating a need to change the structural system

    Toward Implementing HH the Amir Declaration of 2% Electricity Generation by Solar Energy in 2020

    Get PDF
    ABSTRACT The utility solar power plants were reviewed and classified by two basic groups: direct thermal concentrating solar power (CSP) and photovoltaic (PV). CSP as Parabolic Trough Collector (PTC) of 100 MW solar power plants (SPP) is suggested and suitable to provide solar thermal power for Qatar. Although, LFC had enough experience for small projects, it is still need to work in large scale plant such as 100 MW and couple with multi effect distillation (MED) to confirm costs

    Selective Spectrophotometric and Spectrofluorometric Methods for the Determination of Amantadine Hydrochloride in Capsules and Plasma via Derivatization with 1,2-Naphthoquinone-4-sulphonate

    Get PDF
    New selective and sensitive spectrophotometric and spectrofluorometric methods have been developed and validated for the determination of amantadine hydrochloride (AMD) in capsules and plasma. The methods were based on the condensation of AMD with 1,2-naphthoquinone-4-sulphonate (NQS) in an alkaline medium to form an orange-colored product. The spectrophotometric method involved the measurement of the colored product at 460  nm. The spectrofluorometric method involved the reduction of the product with potassium borohydride, and the subsequent measurement of the formed fluorescent reduced AMD-NQS product at 382  nm after excitation at 293  nm. The variables that affected the reaction were carefully studied and optimized. Under the optimum conditions, linear relationships with good correlation coefficients (0.9972–0.9974) and low LOD (1.39 and 0.013 μg mL−1) were obtained in the ranges of 5–80 and 0.05–10  μg mL−1 for the spectrophotometric and spectrofluorometric methods, respectively. The precisions of the methods were satisfactory; RSD ≤2.04%. Both methods were successfully applied to the determination of AMD in capsules. As its higher sensitivity, the spectrofluorometric method was applied to the determination of AMD in plasma; the recovery was 96.3–101.2 ± 0.57–4.2%. The results obtained by the proposed methods were comparable with those obtained by the official metho

    A pre-trained convolutional neural network with optimized capsule networks for chest X-rays COVID-19 diagnosis

    Get PDF
    Coronavirus disease (COVID-19) is rapidly spreading worldwide. Recent studies show that radiological images contain accurate data for detecting the coronavirus. This paper proposes a pre-trained convolutional neural network (VGG16) with Capsule Neural Networks (CapsNet) to detect COVID-19 with unbalanced data sets. The CapsNet is proposed due to its ability to define features such as perspective, orientation, and size. Synthetic Minority Over-sampling Technique (SMOTE) was employed to ensure that new samples were generated close to the sample center, avoiding the production of outliers or changes in data distribution. As the results may change by changing capsule network parameters (Capsule dimensionality and routing number), the Gaussian optimization method has been used to optimize these parameters. Four experiments have been done, (1) CapsNet with the unbalanced data sets, (2) CapsNet with balanced data sets based on class weight, (3) CapsNet with balanced data sets based on SMOTE, and (4) CapsNet hyperparameters optimization with balanced data sets based on SMOTE. The performance has improved and achieved an accuracy rate of 96.58% and an F1- score of 97.08%, a competitive optimized model compared to other related models.Web of Scienc

    Development of (4-Phenylamino)quinazoline Alkylthiourea Derivatives as Novel NF-κB Inhibitors

    Get PDF
    For many inflammatory diseases, new effective drugs with fewer side effects are needed. While it appears promising to target the activation of the central pro-inflammatory transcription factor NF-κB, many previously discovered agents suffered from cytotoxicity. In this study, new alkylthiourea quinazoline derivatives were developed that selectively inhibit the activation of NF-κB in macrophage-like THP−1 cells while showing low general cytotoxicity. One of the best com pounds, 19, strongly inhibited the production of IL-6 (IC50 = 0.84 µM) and, less potently, of TNFα (IC50 = 4.0 µM); in comparison, the reference compound, caffeic acid phenethyl ester (CAPE), showed IC50s of 1.1 and 11.4 µM, respectively. Interestingly, 19 was found to block the translocation of the NF-κB dimer to the nucleus, although its release from the IκB complex was unaffected. Furthermore, 19 suppressed the phosphorylation of NF-κB-p65 at Ser468 but not at Ser536; however, 19 did not inhibit any kinase involved in NF-κB activation. The only partial suppression of p65 phosphorylation might be associated with fewer side effects. Since several compounds selectively induced cell death in activated macrophage-like THP−1 cells, they might be particularly effective in various inflam matory diseases that are exacerbated by excess activated macrophages, such as arteriosclerosis and autoimmune diseases

    Novi analitički pristup sa smanjenom potrošnjom organskih otapala u spektrofotometrijskoj analizi temeljenoj na prijenosu naboja: Primjena u analizi nekih antihipertenziva

    Get PDF
    The present study describes the development of a novel analytical approach that can reduce by 50-fold the consumption of organic solvents in the charge transfer (CT)-based spectrophotometric analysis. The proposed approach employed 96-microwell assay plates for carrying out the reaction. The CT reaction between the electron-donating analyte and electron-accepting reagent was performed in microwells (200-µL of organic solvent) and the color signals were measured with a microwell-plate reader. Optimum conditions for the proposed approach were established for two antihypertensive drugs, namely ramipril (RML) and lisinopril (LSL) as model compounds for the electron-donating analytes, and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) as a -electron acceptor. Under the optimum conditions, Beer’s law was obeyed in the concentration range of 6–100 and 6–60 g mL1 for RML and LSL, respectively. The limits of detection were 0.97 and 1.10 g mL1 for RML and LSL, respectively. The precision of the methods was satisfactory; the values of relative standard deviations did not exceed 1.1 %. The proposed approach was successfully applied to the analysis of pharmaceutical dosage forms with good accuracy and precision. The results were comparable with those of the reported methods. The approach described herein is of great practical value in pharmaceutical analysis because it reduces the exposure of analysts to the toxic effects of organic solvents, lowers the analysis cost by 50-fold, and it has a high throughput property. Although the approach was validated for RML and LSL, the same methodology could be used for any electron-donating analyte for which a CT-reaction can be performed.U radu je opisan razvoj novog analitičkog pristupa koji 50 puta smanjuje potrošnju organskih otapala u spektrofotometrijskoj analizi na bazi prijenosa naboja (CT). Predložena metoda koristi ploče s 96 jažica za izvođenje analize. CT reakcije između elektron-donora i elektron-akceptora izvodi se u jažicama s 200-µL organskog otapala. Promjene boje mjere se pomoću posebnog mikročitača za ploče s jažicama. Određeni su optimalni uvjeti za dva antihipertenzivna lijeka, ramipril (RML) i lizinopril (LSL) koji su upotrebljeni kao modelni spojevi za elektron-donorske analite, i 2,3-diklor-5,6-dicijano-1,4-benzokinon (DDQ) kao -elektronski akceptor. U optimalnim uvjetima Beerov zakon je vrijedio u koncentracijskom području 6–100 i 6–60 g mL1 za RML, odnosno LSL. Granice detekcije bile su 0,97 i 1,1 g mL1 za RML, odnosno LSL. Preciznost metode bila je zadovoljavajuća, a relativna standardna devijacija bila je manja od 1,1 %. Predložena metoda uspješno je primijenjena za analizu doziranih farmaceutskih pripravaka koji sadrže ispitivane lijekove, uz dobru točnost i preciznost. Rezultati predložene metode usporedivi su s rezultatima poznatih metoda. Postupak opisan u ovom radu vrlo je praktičan: analitičari su manje izloženi toksičnim učincima organskih otapala, troškovi analize smanjeni su 50 puta, a također ju odlikuje visoka propusnost. Iako je postupak validiran za RML i LSL, ista metoda može se upotrijebiti za elektron-donirajući analit koji ulazi u CT reakciju

    Osjetljiva spektrofotometrijska metoda za određivanje antagonista H2-receptora uz uporabu N-bromsukcinimida i p-aminofenola

    Get PDF
    A simple, accurate and sensitive spectrophotometric method for determination of H2-receptor antagonists: cimetidine (CIM), famotidine (FAM), nizatidine (NIZ), and ranitidine hydrochloride (RAN) has been full developed and validated The method was based on the reaction of these drugs with NBS and subsequent measurement of the excess N-bromosuccinimide by its reaction with p-aminophenol to give a violet colored product (max at 552 nm). Decrease in the absorption intensity (A) of the colored product, due to the presence of the drug, was correlated with its concentration in the sample solution. Different variables affecting the reaction were carefully studied and optimized. Under optimal conditions, linear relationships with good correlation coefficients (0.9988-0.9998) were found between A values and the corresponding concentrations of the drugs in a concentration range of 830, 622, 625, and 420 g mL1 for CIM, FAM, NIZ, and RAN, respectively. Limits of detection were 1.22, 1.01, 1.08, and 0.74 g mL1 for CIM, FAM, NIZ, and RAN, respectively. The method was validated in terms of accuracy, precision, ruggedness, and robustness; the results were satisfactory. The proposed method was successfully applied to the analysis of the above mentioned drugs in bulk substance and in pharmaceutical dosage forms; percent recoveries ranged from 98.5 0.9 to 102.4 0.8% without interference from the common excipients. The results obtained by the proposed method were comparable with those obtained by the official methods.Razvijena je i validirana ispravna, jednostavna i osjetljiva spektrofotometrijska metoda za određivanje antagonista H2-receptora: cimetidina (CIM), famotidina (FAM), nizatidina (NIZ) i ranitidin hidroklorida (RAN). Metoda se temelji na reakciji tih ljekovitih tvari s N-bromsukcinimidom (NBS). Višak N-bromsukcinimida određuje se nakon reakcije s p-aminofenolom s kojim daje ljubičasti produkt (max pri 552 nm). Smanjenje apsorpcijskog intenziteta (A) obojenog produkta, zbog prisutnosti ljekovite tvari korelirano je s njegovom koncentracijom u otopini uzorka. Proučavane su različite varijable koje utječu na reakciju. Linearno koncentracijsko područje za CIM, FAM, NIZ i RAN, s koeficijentom korelacije od 0,9988 do 0,9998, iznosi 830, 622, 625 odnosno 420 g mL1. Granice detekcije bile su 1,23, 1,02, 1,09 i 0,75 g mL1 za CIM, FAM, NIZ, odnosno RAN. Predložena metoda je uspješno primijenjena za analizu navedenih ljekovitih tvari i ljekovitih pripravaka. Nepreciznost od 0,7 do 1,2% i visoka ispravnost (analitički povrat između 98,5 i 102,4%), bez interferencije uobičajenih pomoćnih tvari, ukazuju na dobru analitičku metodu. Rezultati dobiveni predloženom metodom usporedivi su s rezultatima dobivenim službenom metodom

    The diagnostic accuracy of intraoperative frozen section biopsy for diagnosis of sentinel lymph node metastasis in breast cancer patients: a meta-analysis

    Get PDF
    : Sentinel lymph node (SLN) sampling is important for evaluating the nodal stage of breast cancer when the axillary nodes are clinically free of metastasis. The intraoperative frozen section (IFS) of SLN is used for lymph node assessment. This meta-analysis aims to provide evidence about the diagnostic accuracy and the applicability of IFS of SLN in breast cancer patients. Data were collected by searching PubMed, Cochrane, Scopus, and Web of Science electronic databases for trials matching our eligibility criteria. The statistical analysis included the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and pooled studies' diagnostic odds ratio outcomes. The analyses were conducted using the Open Meta-analyst software. This meta-analysis pooled the results of 110 studies. The overall sensitivity of IFS for SLN metastasis was 74.7%; 95% CI [72.0, 77.2], P < 0.001. It was 31.4% 95% CI [25.2, 38.3], P < 0.001 for the micro-metastasis, and 90.2%; 95% CI [86.5, 93.0], P < 0.001 for the macro-metastasis. The overall specificity was 99.4%; 95% CI [99.2, 99.6], P < 0.001. The overall positive likelihood ratio was 121.4; 95% CI [87.9, 167.6], P < 0.001, and the overall negative likelihood ratio was 0.226; 95% CI [0.186, 0.274], P < 0.001. The overall diagnostic odds ratio of IFS for diagnosing SLN metastasis was 569.5; 95% CI [404.2, 802.4], P < 0.001. The intraoperative frozen section of SLN has good sensitivity for diagnosing breast cancer macro-metastasis. However, the sensitivity is low for micro-metastasis. The specificity is very satisfactory
    corecore